 Panel Meters and Controllers Panel Meter Modular Series EDM 35
* Modular digital panel meter, 3 1/2-digit * Indicating or controlling current, voltage, resistance, temperature, tacho or frequency. * Easy programming * Programmable hysteresis and time delay (up to 2 setpoints) * Data hold * Peak/valley function * Password protection of programming parameters * Stock-saving - several ranges on each input module * IP 65 (front) * Optional hardware lock of programming * Optional high-efficiency red or green display
Product Description
The EDM 35 is a 3 1/2-digit, modular digital panel meter where input and output modules can be combined to suit many applications. Scaling and setpoints are fully programmable and the programming itself is very user-friendly. Furthermore, the EDM 35 includes peak/valley function and password protection. The housing is easy to mount and ensures a protection degree of IP 65.
Ordering Key
Main unit Range Power supply Relay output Signal output Options
EDM35V1D41XXX
Type Selection
Range DC Voltmeters: V1D: -199.9 to +199.9 mV V2D: -1.999 to +1.999 V V3D: -19.99 to +19.99 V V4D: -199.9 to +199.9 V V5D: -600 to +600 V * Range AC Voltmeters: V1A: 0 to 199.9 mV V2A: 0 to 1.999 V V3A: 0 to 19.99 V V4A: 0 to 199.9 V V5A: 0 to 600 V * Range Ohmmeters: R1D: 0 to 199.9 R2D: 0 to 1.999 k R3D: 0 to 19.99 k R4D: 0 to 199.9 k Range DC Ammeters: A1D: -199.9 to +199.9 A A2D: -1.999 to +1.999 mA A3D: -19.99 to +19.99 mA A4D: -199.9 to +199.9 mA A5D: -1999 to +1999 mA A6D: -5.00 to +5.00 A A7D: -10.00 to +10.00 A
* Nominal voltage according to IEC 60664-1. The measuring range includes 15% tolerance equal to 690 V. Range AC Ammeters: A1A: 0 to 199.9 A A2A: 0 to 1.999 mA A3A: 0 to 19.99 mA A4A: 0 to 199.9 mA A5A: 0 to 1999 mA A6A: 0 to 5.00 A A7A: 0 to 10.00 A Range Thermometers: Pt 100: P1C: -100.0 to 199.9C P2C: -100 to 850C P1F: -148.0 to 199.9F P2F: -148 to 392F P3F: -148 to 1562F Thermocouple Type J: -JC: -100 to 760C -JF: -148 to 1400F Thermocouple Type K: -KC: -100 to 1250C -KF: -148 to 1999F Relay Output: 0: None 1: 1 Relay 2: 2 Relays Power Supply: 3: 12 to 48 VDC 4: 230 VAC 5: 115 VAC 6: 48 VAC 7: 24 VAC Range Frequency Meters: F1X*: 5.0 to199.9 Hz F2X*: 10.0 to 1999 Hz * Replace X with: A for Namur input B for NPN, PNP & Contact input C 600 VAC input Signal Output: X: None 1: 4 to 20 mA 2: 0 to 20 mA 4: 0 to 10 V 5: Transducer power supply 12 VDC 6: Transducer power supply 24 VDC Contact factory for other output signals
Options: XX: None CX: High eff. red display DX: Green display XP: Program lock 01-99: Special options (assigned by factory)
Specifications are subject to change without notice (27.10.99)
1
Series EDM 35
Type Selection (cont.)
Range Tachometers: T1X*: 8.0 to 199.9 rpm @30 ppr** T2X*: 5.0 to 199.9 rpm @60 ppr** T3X*: 2.0 to 199.9 rpm @100 ppr** T4X*: 20 to 1999 rpm @30 ppr** T5X*: 10 to 1999 rpm @60 ppr** T6X*: 10 to 1999 rpm @100 ppr** * Replace X with: A for Namur input B for NPN, PNP & Contact input ** pulses per revolution
Separate Ordering Numbers
Main unit (mechanical parts included) Red display (standard red) Red display (high-bright red) Green display Input modules VDC VAC ADC AAC AAC/ADC 10 A Ohm Pt 100 Pt 100 850C Thermocouple Type J Thermocouple Type K Tachometer Frequency meter Output modules 1 Relay 2 Relays Analog output 12/24 VDC excitation output Power supply modules 12 to 48 VDC 24 VAC 48 VAC 115 VAC 230 VAC Ordering number 5100511 5100512 5100510 With Program Lock 5100630 5100631 5100632 5100633 5100634 5100635 5100636 5100639 5100637 5100638 5100640 5100641
Input Specifications - General
Power supply EMC Immunity Input modules supplied by main unit Electromagnetic compatibility Acc. to IEC 60801-4 Acc. to IEC 60801-5
5100530 5100531 5100532 5100533 5100534 5100535 5100536 5100539 5100537 5100538 5100540 5100541 5100561 5100562 5100560 5100526 5100524 5100523 5100522 5100521 5100520
Supply Specifications
Power supply AC Rated operational voltage Overvoltage cat. III (IEC 60664) 230 VAC 10% 115 VAC 10% 48 VAC 10% 24 VAC 10% 50/60 Hz 5Hz 20 ms 250 VAC basic rms 6 kV (1.2/50 s) IEC 60664-1 12 to 48 VDC 15% 10 ms (voltage = 10 VDC) 150 VDC basic 4.0 kV (1.2/50 s) IEC 60664-1 < 7 VA Electromagnetic compatibility Acc. to IEC 60801-4 Acc. to IEC 60801-5
General Specifications
Display 7-segment LED, height 14.2 mm 2 LEDs for indication of relay ON -1999/1999 EE (underrange: -EE) See module specifications See module specifications Progr. within whole range Progr. within whole range Programmable Screw terminals IP 65 (front) IP 20 (behind panel) 0 to +50C. R.H. < 90% non-condensing -10 to +60C. R.H. < 90% non-condensing Approx. 350 g depends on modules used 48 x 96 x 89 mm ABS/Polycarbonate blend Polycarbonate Black housing Red front with red display Grey front with green display UL, CSA, SEV
Frequency Voltage interruption Rated insulation voltage Rated impulse withstand voltage Power supply DC Rated operational voltage Voltage interruption Rated insulation voltage Rated impulse withstand voltage Rated operational power EMC Immunity
Min./Max. indication Overrange indication Accuracy Temperature drift Scaling Electrical input range Display range Decimal point position Module connection Environment Degree of protection Operating temperature Storage temperature Weight Housing Dimensions Housing material Front material Colour
Approvals
2
Specifications are subject to change without notice (27.10.99)
Series EDM 35
Input Specifications - Modules
Voltmeters - AC/DC (5100531/5100530, 5100631/5100630)
Measuring Jumper ranges position Range code Resolution Input imped. AC DC
Thermometers (5100536/5100537/5100538, 5100539/5100636/5100637/5100638/5100639)
Range Pt 100: -100.0 to 199.9C -148.0 to 199.9F 1F Pt100, 850C: -100 to 850C -148 to 1562F Reso- Accuracy lution 0.1C 0.2% of reading 2 dgt 0.2F 0.2% of reading 4 dgt 0.10 dgt/F 0.2% of reading 4 dgt 0.10 dgt/F 1C 2F 0.2% of reading 3 dgt 0.4% of reading 6 dgt Temperature drift 150 ppm/C 0.05 dgt/C 180 ppm/F -148 to 392F 180 ppm/F 150 ppm/C 0.05 dgt/C 180 ppm/F 0.1 dgt/F 100 ppm/C 0.05 dgt/C 180 ppm/F 100 ppm/C 0.05 dgt/C 100 ppm/C 0.05 dgt/C 100 ppm/C 0.05 dgt/C 100 ppm/C 0.05 dgt/C 180 ppm/F -148 to -58F 180 ppm/F 0.1 dgt/F 180 ppm/F 1436 to 180 ppm/F 0.1 dgt/F
199.9 mV 1-4 7 1 0.1 mV 100 k 1.999 V 2-5 8 2 1 mV 100 k 19.99 V 2-5 9 3 10 mV 1 M 199.9 V 3-6 10 4 0.1 V 1 M 600 V * 5-6 12 6 1V 1 M * Nominal voltage according to IEC 664-1. The measuring range includes 15% tolerance equal to 690 V. Accuracy AC voltmeter DC voltmeter Temperature drift AC voltmeter DC voltmeter
0.3% of reading 3 dgt 0.2 % of reading 2 dgt 150 ppm/C 0.2 dgt/C 100 ppm/C 0.05 dgt/C
Ammeters - AC/DC(5100533/5100532/ 5100534, 5100633/5100632/5100634)
Measuring ranges 199.9 A 1.999 mA 19.99 mA 199.9 mA 1999 mA 5.00 A Jumper position 1-2 2-3 4-5 5-6 2-5 2-5 Range code AC DC 7 8 9 10 11 12 12 1 2 3 4 5 6 6 Resolution
0.1 A 1 A 10 A 0.1 mA 1 mA 10 mA 10 mA 10 mA
10 AAC 2-3 10 ADC 1-2 Accuracy AC ammeter AC ammeter (10 A) DC ammeter DC ammeter (10 A) Temperature drift AC ammeter AC ammeter (2 A, 5 A) AC ammeter (10 A) DC ammeter DC ammeter (2 A, 5 A) DC ammeter (10 A) Voltage drop
0.1% of reading 4 dgt -148 to 1400F 1F 0.1% of reading 8 dgt 0.1 dgt/F Thermocouple type K: -100 to 1250C 1C 3% of reading 3 dgt -100 to -50C 1C 1% of reading + 5/-1 dgt -50 to 780C 1C 0.1% of reading 3 dgt 780 to 1250C 1C 0.25% of reading + 1/-3 dgt -148 to 1999F 2F 3% of reading 6 dgt 0.1 dgt/F 2F 1% of reading + 10/-2 dgt -58 to 1436F 2F 0.1% of reading 6 dgt 0.1 dgt/F 1999F 2F 0.25% of reading +2/-6 dgt
Thermocouple type J: -100 to 760C 1C
0.3% of reading 3 dgt 0.5% of reading 5 dgt 0.2 % of reading 2 dgt 0.5% of reading 5 dgt 150 ppm/C 0.5 dgt/C 200 ppm/C 0.1 dgt/C 200 ppm/C 0.5 dgt/C 100 ppm/C 0.05 dgt/C 200 ppm/C 0.5 dgt/C 200 ppm/C 0.5 dgt/C < 200 mV (all ranges)
Ohmmeters (5100535, 5100635)
Measuring ranges 199.9 1.999 k 19.99 k 199.9 k Jumper position 1-4 2-5 3-6 1-2 Rangecode 7 8 9 10 Resolution 0.1 1 0.01 k 0.1 k
Accuracy Temperature drift
0.2% of reading 2 dgt 150 ppm/C 0.1 dgt/C
Specifications are subject to change without notice (27.10.99)
3
Series EDM 35
Input Specifications - Modules (cont.)
Tachometers (5100540, 5100640)
Measuring ranges 199.9 rpm @30 ppr* 199.9 rpm @60 ppr* 199.9 rpm @100 ppr* 1999 rpm @30 ppr* 1999 rpm @60 ppr* 1999 rpm @100 ppr* * pulses per revolution Input selection Namur NPN, PNP, Contact Accuracy Temperature drift Input impedance Namur NPN, PNP and Contact Time constant (tc) Jumper position J4, 1-2 J5, 1-2 J6. 1-2 J4, 2-3 J5, 2-3 J6, 2-3 Range code 7 8 9 10 11 12 Resolution 0.1 RPM 0.1 RPM 0.1 RPM 1 RPM 1 RPM 1 RPM
Frequency Meters (5100541, 5100641)
Measuring ranges 199.9 Hz 1999 Hz Jumper position J7 J8 Range code 7 8 Resolution 0.1 Hz 1 Hz
J1 J2 1% of reading 5 dgt 200 ppm/C 1 k 5 k 1 sec.
Input selection Namur NPN, PNP, Contact 600 VAC Accuracy Temperature drift Input impedance Namur NPN, PNP and Contact 600 VAC Time constant (tc)
J1, J4 and J6 J2 and J5 J3 1% of reading 5 dgt 200 ppm/C 1 k 5 k 600 k 1 sec.
Output Specifications
Excitation output (5100526)
Power supply Output voltage 12 VDC: jumper position 24 VDC: jumper position Output current 12 VDC 24 VDC EMC Immunity Supplied by main unit 3 - 6, tolerance 20% 1 - 4, tolerance 20% 35 mA DC 20 mA DC Electromagnetic compatibility Acc. to IEC 60801-4 Acc. to IEC 60801-5
Relay output 1 or 2 relays (5100561/5100562)
Power supply Output Rated insulation voltage Contact ratings (AgCdO) Resistive AC 1 DC 1 Small inductive loads AC 15 DC 13 Mechanical life Electrical life Supplied by main unit 1 or 2 SPDT relays 250 V basic rms 5 A, 250 VAC 5 A, 24 VDC 2 A, 250 VAC 3 A, 24 VDC 40 x 106 operations 105 operations (at max. load) max. 10 Hz (50% duty cycle)
Analogue output (5100560)
Measuring ranges 0 to 20 mA 4 to 20 mA 0 to 10 V Load resistance 500 500 1,000 1% of reading 0.1 mA 1% of reading 0.1 mA 1% of reading 0.05 V 200 ppm/C yes
Operating frequency Dielectric strength Dielectric voltage 2 kVAC (rms) Rated impulse withstand volt. 4 kV (1.2/50 s)
Accuracy 0 to 20 mA 4 to 20 mA 0 to 10 V Temperature drift Short-circuit protection
4
Specifications are subject to change without notice (27.10.99)
Series EDM 35
Wiring Diagrams
*) *) *) *) *) *)
Power supply
5100520-23 *)
5100524 *)
5100526 *)
5100560 *)
5100561 *)
5100562 *)
5100530 *)
5100531 *)
5100532 *)
5100533 *)
5100534 *)
5100535
5100536 Modules with type nos. xxxx63x are equipped with Program Lock function. *) Module position (slot) in the base unit is indicated by a drawing on the plastic cover.
5100537
5100538
5100540 Note. By short-circuiting terminals marked "HOLD" (supply module), it is possible to hold the displayed value indefinitely (hold function). The comparison of the input variable with the alarm setpoint remains active. To reactivate the display, remove the short-circuit.
5100541
Caution! Since the input circuitry is not galvanically isolated, the potential of the measured variable will be present on all connections to the unit (i.e. "Hold" input). This is of special importance when measuring line voltage and current.
Specifications are subject to change without notice (27.10.99)
5
Series EDM 35
Front Panel Description
2 2. Display 3 1/2-digit (maximum read-out 1999). Alphanumeric indication by means of 7-segment display for: - Displaying of the measured value. - Indication of programming parameters. 3. LED - "1" and "2" LED indicators for alarm conditions. 1 1. Keyboard S Set/enter Up Down
mV = 01 V = 02 kV = 03 A = 04 mA = 05 A = 06 mW = 07
3
4
4. Engineering unit Screen for interchangeable unit label.The symbols in the greyish areas are those available on the set of engineering unit labels supplied with the EDM. (Engineering unit label to be inserted by customer.)
W = 08 kW = 09 MW = 10 var = 11 kvar = 12 Mvar = 13 = 14 k = 15
M = 16 Hz = 17 kHz = 18 RPM = 19 m/s = 20 m/min = 21 C = 22
% = 24 mm HG = 32 mbar = 25 bar = 26 psi = 27 ata = 28 ate = 29 kg/cm2 = 30 l/min = 33 l/h = 34 kg/min = 35 ton/h = 36 m2/min = 37 m2/h = 38 mm = 39
cm = 40 m = 41 kg = 42 ppm = 43 kA = 44 cos = 45 m3 = 46 s = 47
Set-up and programming procedures are easily controlled by the three pushbuttons. Set/Enter key: - Entry of variables. - Selecting programming functions. Up and Down key for: - Display control. - Increasing or decreasing programming value. - Selecting programming functions and instrument configuration together with the S key.
F = 23 mm H2O = 31
Operation Diagrams
Setpoint Operation Scaling Operation
6
Specifications are subject to change without notice (27.10.99)
Series EDM 35
Mode of Operation
Depending upon the input modules used, it is possible to measure AC/DC (current or voltage), resistance (the range is selected with a jumper on the input module) or temperature (Pt 100 or Thermocouple J/K). Without an output module, the EDM is an indicator - by inserting an output module the EDM is a controller. The input range and the display range are fully programmable, and so are the setpoint(s) if a relay output module is inserted. A hold function is available for freezing a measured value. Passwords 0 to 99 are for overall programming while passwords 100 to 199 allow direct set-point programming outside the password protection. See user manual for further details.
Modules and Slot Position
Rear view of main unit Slot #1 Slot #2 Slot #3 Slot #4 Slot #5
Settings
Programmable setting: Jumper setting: See user manual. See user manual.
Input Module: VAC VDC AAC ADC 10A AC/DC Pt 100 Thermo couple Tachometer Frequency
Output Module: Excitation output Analogue output
Power Supply module: 24 VAC 48 VAC 115 VAC 230 VAC 12-48 VDC
Output Module: 1 Relay output 2 Relay outputs
Overall Dimensions and Panel Cutout
Front view Side view
Top view
Panel cutout
Panel
All dimensions in mm.
Specifications are subject to change without notice (27.10.99)
7


▲Up To Search▲   

 
Price & Availability of EDM35V1D41

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X